Fully automatic and laser-assisted centering device for hardness measurement on plane-parallel plates and O-rings without user influence. The Barofix 4 is used in combination with the digi test II.
Power supply 100 - 240 VAC; 50 / 60 Hz via digi test II
Protection class IP 20
Measurements 310 x 144 x 204 mm
Weight approx. 3300 g
Repeatability thickness measurement 0,03 mm
Thickness measurement resolution 0,01 mm
Table positioning accuracy 0,08 mm
O-ring cord from/to 1 - 15 mm
Metrological traceability (VIM 2.41): Property of a measurement result, whereby the result can be traced back to a reference, through a documented, uninterrupted chain of calibrations, each of which contributing to the measurement uncertainty.
In accordance with the calibration rhythm you have set, you will receive an automatic reminder that your hardness tester has to be calibrated soon, as a special service from our company. With the purchase of a new device, this reminder is initially sent annually, but it can be set at a specific interval you desire. You will usually receive the reminder approximately one month before the due date.
When it comes to determining the calibration rhythm, an optimum should be found between the calibration costs and the error costs.
We are happy to answer any questions you might have about hardness testing!
Telephone +49 7305 9642-0
Fax +49 7305 9642-22
Email
Opening hours:
Monday – Thursday: 07.00 a.m. - 16.00 p.m.
Friday: 07.00 a.m. - 12.00 p.m.
The automatic O-ring positioning device for digi test II.
Fully automatic and laser-assisted centering device for hardness measurement on plane-parallel plates and O-rings without user influence. The Barofix 4 is used in combination with the digi test II.
Power supply 100 - 240 VAC; 50 / 60 Hz via digi test II
Protection class IP 20
Measurements 310 x 144 x 204 mm
Weight approx. 3300 g
Repeatability thickness measurement 0,03 mm
Thickness measurement resolution 0,01 mm
Table positioning accuracy 0,08 mm
O-ring cord from/to 1 - 15 mm
Metrological traceability (VIM 2.41): Property of a measurement result, whereby the result can be traced back to a reference, through a documented, uninterrupted chain of calibrations, each of which contributing to the measurement uncertainty.
In accordance with the calibration rhythm you have set, you will receive an automatic reminder that your hardness tester has to be calibrated soon, as a special service from our company. With the purchase of a new device, this reminder is initially sent annually, but it can be set at a specific interval you desire. You will usually receive the reminder approximately one month before the due date.
When it comes to determining the calibration rhythm, an optimum should be found between the calibration costs and the error costs.
We are happy to answer any questions you might have about hardness testing!
Telephone +49 7305 9642-0
Fax +49 7305 9642-22
Email service@bareiss.de
Opening hours:
Monday – Thursday: 07.00 a.m. - 16.00 p.m.
Friday: 07.00 a.m. - 12.00 p.m.
Downloads
„Werfen Sie einen Blick in unsere Produktionsstätte in Oberdischingen und entdecken Sie, mit welcher Präzision unsere Härteprüfgeräte gefertigt werden. “
Request a quote